Patient Monitor — SUN-603S

This patient monitor measures key parameters, including ECG, RESP, SpO₂, NIBP, and dual-channel temperature. It combines a measurement module, display, and recorder into a compact, portable design. Additionally, its built-in, replaceable battery ensures convenience for patient mobility.

Contact us for pricing!

Sun-Fri 9 AM to 5 PM
SKU: RPLPM603S Category:

Product Features

  • Elegant design with clear markings, a standard interface, an OxyCRG screen, trend graphs, large characters, and multi-bed observation for user convenience.
  • Suitable for adults, pediatric, and neonatal patients.
  • Standard parameters: ECG, RESP, NIBP, SpO₂, and dual-channel TEMP. Optional features include IBP, CO₂ monitoring, a built-in printer, a curved handle, a mobile stand, and a wall-mount bracket.
  • User-friendly interface available in Chinese and English, operated via buttons and knobs. Optional languages: French, German, Italian, Dutch, Portuguese, Turkish, Spanish, Polish.
  • 12.1” high-resolution color TFT LCD displays patient parameters, waveforms, alarms, bed number, clock, system status, and other essential information in real time.
  • Customizable monitoring settings, including scan speed, volume, and output content.
  • Stores up to 480 hours of trend data with a 40-second holographic waveform review.
  • Stores and reviews 72 hours of ECG waveform data.
  • NIBP review function with storage for up to 2400 NIBP measurements.
  • Advanced digital SpO₂ technology with strong anti-interference and low-perfusion detection capability.
  • Drug concentration calculation feature.
  • Networking capability: Connects to a central monitoring station, supports multi-bed observation, and allows software updates via wired or wireless connections.
  • Built-in rechargeable battery ensures uninterrupted monitoring.
  • Resistant to high-frequency surgical interference and defibrillation-proof (requires special leads).
  • Optional heart rate variability (HRV) analysis function.

Product Specifications

Weight 4.8 kg
Dimensions 38 × 35 × 30 cm
Place of Origin

Shanghai, China

Power Source

Electricity

Warranty

1 year

Material

Metal, Plastic

Shelf Life

1 Year

Quality Certification

CE (Conformité Européenne)

Instrument Classification

Class II

Display Size(Diagonal)

12.1-inch

Display Panel Technology

TFT

Display Type

Color

Display Resolution

800×600

Extended Specifications

Type

Vital Sign Machine

Application

Adult, Pediatric and Neonatal

ECG Channels

3-Channel, 5-Channel

ECG Lead Configuration

3/5 Lead ECG

Parameters Monitored

ECG, RESP, NIBP, SPpO2, 2-TEMP, PR, 2-IBP, CO2

Electrocardiogram (ECG)

Yes

Respiration Rate (RESP)

Yes

Non-Invasive Blood Pressure (NIBP)

Yes

Pulse Oximetry (SpO₂)

Yes

Dual Temperature (2-TEMP)

Yes

Pulse Rate (PR)

Yes

Dual Invasive Blood Pressure (2-IBP)

Yes

Capnography (CO₂)

Yes

NIBP Storage

2400 measurements

Holographic waveform review duration

40 seconds

Built-in Printer

Yes

Power Supply

220V, 50Hz

Multi-Languages

Spanish, French, English, Portuguese, Turkish, German and so on.

Safety Standard

Class II

ECG Performance

  • Lead Mode: 3-lead (Optional), 5-lead (Optional)
  • Lead Selection: I, II, III, AVR, AVL, AVF, V
  • Waveform:
    • 5-lead: 2 channels
    • 3-lead: 1 channel
  • Gain: ×2.5 mm/mV, ×5.0 mm/mV, ×10 mm/mV, ×20 mm/mV
  • Heart Rate (HR) Measuring and Alarm Range:
    • Range: 15 ~ 300 bpm
    • Accuracy: ±1% or ±1 bpm (whichever is greater)
    • Alarm Accuracy: ±2 bpm
    • Resolution: 1 bpm
  • CMRR (Common Mode Rejection Ratio):
    • Monitor: ≥100 dB
    • Surgery: ≥100 dB
    • Diagnosis: ≥60 dB

Bandwidth Performance

  • Surgery: 1 ~ 20 Hz (+0.4 dB, -3 dB)
  • Monitor: 0.5 ~ 40 Hz (+0.4 dB, -3 dB)
  • Diagnosis:
    • 0.05 ~ 75 Hz (+0.4 dB, -3 dB)
    • 76 Hz ~ 150 Hz (+0.4 dB, -4.5 dB)

Calibration Signal

1 mV (Vp-p), ±5% Accuracy

ST Segment Monitoring

Measuring and Alarm Range: -0.6 mV ~ +0.8 mV

ARR(Arrhythmia) Detecting Type

  • ASYSTOLE: A flatline or absence of electrical activity in the heart.
  • VFIB/VTAC: Ventricular Fibrillation and Ventricular Tachycardia, dangerous heart rhythms.
  • COUPLET: Two premature heartbeats occurring consecutively.
  • BIGEMINY: A pattern where every other heartbeat is abnormal.
  • TRIGEMINY: A pattern where every third heartbeat is abnormal.
  • R ON T: A condition where a premature heartbeat occurs on the T wave of the preceding beat.
  • VT>2: Ventricular Tachycardia with more than 2 beats.
  • PVC: Premature Ventricular Contraction, an early heartbeat originating from the ventricles.
  • TACHY: Tachycardia, a fast heart rate.
  • BRADY: Bradycardia, a slow heart rate.
  • MISSED BEATS: Skipped or missed heartbeats.
  • PNP: Premature Normal Pulse.
  • PNC: Premature Normal Contraction.

Alarm

Available

Review

Available

Scan Speed for ECG Waveform (Adjustable)

  • 12.5 mm/s: Accuracy ±10%
  • 25 mm/s: Accuracy ±10%
  • 50 mm/s: Accuracy ±10%

Respiration Performance

  • Method: R-F (RA-LL) Impedance
  • Differential Input Impedance: >2.5 MΩ
  • Measuring Impedance Range: 0.3 ~ 5.0 Ω
  • Baseline Impedance Range: 100 Ω – 2500 Ω
  • Bandwidth: 0.3 ~ 2.5 Hz

RESP Rate Performance

  • Measuring and Alarm Range: 0 ~ 120 rpm
  • Resolution: 1 rpm
  • Measuring Accuracy: ±2 rpm
  • Alarm Accuracy: ±3 rpm
  • Apnea Alarm: 10 ~ 40 s

NIBP (Non-Invasive Blood Pressure) Performance

  • Method: Oscillometry
  • Mode: Manual, Auto, Continuous
  • Measuring Interval in AUTO Mode: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 240, 480, 960 min
  • Measuring Period in Continuous Mode: 5 min
  • Measuring and Alarm Range: 10 ~ 270 mmHg
  • Alarm Type: SYS, DIA, MEAN

Resolution

  • Pressure: 1 mmHg
  • Cuff Pressure: ±3 mmHg
  • Accuracy: ±10% or ±8 mmHg, whichever is greater

Over-pressure Protection

  • Adult Mode: 315 ±10 mmHg
  • Pediatric Mode: 265 ±10 mmHg
  • Neonatal Mode: 155 ±10 mmHg

SpO₂ (Pulse Oximetry) Performance

  • Measuring Range: 0 ~ 100%
  • Alarm Range: 0 ~ 100%
  • Resolution: 1%
  • Accuracy: 70% ~ 100% ±2%
  • Accuracy (0% ~ 69%): Unspecified

Pulse Rate (PR) Performance

  • Measuring and Alarm Range: 0 ~ 250 bpm
  • Resolution: 1 bpm
  • Measuring Accuracy: ±2 bpm or ±2%, whichever is greater
  • Alarm Accuracy: ±2 bpm

TEMP (Temperature) Performance

  • Channel: Dual-channel
  • Measuring and Alarm Range: 0 ~ 50°C
  • Resolution: 0.1°C
  • Accuracy: ±0.1°C
  • Actualization Interval: About 1 sec.
  • Average Time Constant: < 10 sec.
  • Alarm Responding Time: ≤ 2 min

ETCO2(End-Tidal Carbon Dioxide) Performance

  • Method: Sidestream or Mainstream
  • Measuring Range for CO2: 0 ~ 150 mmHg
  • Resolution for CO2:
    • 0.1 mmHg (for 0 to 69 mmHg)
    • 0.25 mmHg (for 70 to 150 mmHg)
  • Accuracy for CO2:
    • 0 – 40 mmHg: ±2 mmHg
    • 41 – 70 mmHg: ±5%
    • 71 – 100 mmHg: ±8%
    • 101 – 150 mmHg: ±10%
  • Respiration Rate >80 BPM: ±12%
  • AwRR Range: 2 ~ 150 rpm
  • AwRR Accuracy: ±1 BPM
  • Apnea Alarm: Available

IBP(Invasive Blood Pressure) Performance

  • Channel: Dual-channel
  • Label: ART, PA, CVP, RAP, LAP, ICP, P1, P2
  • Measuring and Alarm Range: -50 ~ 350 mmHg
  • Resolution: 1 mmHg
  • Accuracy: ±2% or 1 mmHg, whichever is greater

Included Accessories

Patient Monitor — SUN-603S includes following accessories:
  1. Adult SpO2 Probe(5-pin): 1 set
  2. Adult NIBP Cuff: 1 set
  3. Extending Tube for Blood Pressure: 1 set
  4. ECG Lead: 1 set
  5. ECG Electrode: 1 set
  6. Temperature Probe: 1 set
  7. Power Cord: 1 set
  8. Thermal Recording Paper: 1 set (Optional)
  9. User Manual: 1 set
"Product specifications and details are provided by the manufacturer and are for reference only. While we strive to ensure accuracy, we cannot guarantee that all information is complete, up-to-date, or error-free. If you have any questions or require confirmation, please contact us before making a purchase."

Find the perfect solutions for your healthcare setting.

Request information on your medical equipment needs and requirements.